Chicago Pneumatic Light Towers · Denver, Colorado

Chicago Pneumatic CPLT V17 LED Light Tower

Four 350 W SMD LED floodlights, 225,600 lumens, a 24 ft mast, and 105 hours of runtime on a single 26 gallon tank. SMD rather than COB LED, which is where the 20 percent extra coverage comes from.

Same Day Shipping on orders by 4 PM Eastern · Crowder Supply, 5635 Franklin St, Denver CO · Stocking Chicago Pneumatic dealer

The short version

One model, and it is a lot of light. The CPLT V17 KH covers 79,222 sq ft at an average of 2 foot-candles, or 45,800 sq ft holding a 0.5 foot-candle minimum. It burns 0.24 gal/h with all four lights on, so a single fill runs more than four nights unattended. The mast rotates 340 degrees by hand and the tower is rated stable to 68 mph wind. Not yet set up for online checkout — call 1-888-883-5144 for pricing, options and lead time. Need power as well as light? See CP portable generators.

CPLT V17 KH

CPLT V17 KH · 60 Hz · Tier 4 Final

CP CPLT V17 KH Portable LED Light Tower

SMD LED technology delivers 20 percent more coverage than COB LED at the same draw, and the low-consumption Kohler KDW702 two-cylinder diesel is sized to match rather than oversized. The RedRock canopy sits on an undercarriage trailer frame with a low centre of gravity.

Choose it when: You need one tower to light a whole work area rather than three to cover the corners, and you would rather refuel weekly than nightly.

Key specs
Floodlights4 x 350 W SMD LED
Total output225,600 lm
Coverage at 2 ft-c average79,222 sq ft
Coverage at 0.5 ft-c minimum45,800 sq ft
Mast height / rotation24 ft / 340 degrees, manual
Fuel autonomy105 h, all lights on
Fuel consumption0.24 gal/h
Wind stability68 mph
Call to QuoteOptions and freight quoted togetherCall 1-888-883-5144

Full technical specification

CPLT V17 KH
Lamps
Number of lights4
TechnologySMD LED
Floodlight power350 W each
Total lumens225,600 lm
Performance
Light coverage, 2 ft-c average79,222 sq ft
Light coverage, 0.5 ft-c minimum45,800 sq ft
Rated frequency / voltage60 Hz / 120 Vac
Power output2.4 kW
Operating temperature14 to 120 degrees F
Altitude capability11,483 ft
Max relative humidity85 percent
Sound power (LWA)90 dB(A)
Sound pressure (LpA) at 23 ft68 dB(A)
Fuel tank capacity26 gal
Fuel consumption, all lights on0.24 gal/h
Fuel autonomy, all lights on105 h
Oil service interval250 h
Mast height24 ft
Mast type / rotationManual / 340 degrees
Wind speed stability68 mph
Engine
Brand and modelKohler KDW702
Speed1,800 rpm
Rated net output (PRP)6 kW
Cylinders / aspiration2 / natural, direct injection
Speed governorMechanical
Emission stageTier 4 Final
Electrical system12 Vdc
Alternator
Brand and modelACA132BL
Rated output4 kVA
Protection degree / insulationIP23 / class H
Canopy, dimensions and weight
Canopy / typeRedRock / undercarriage
Transport L x W x H75 x 48 x 91 in.
Operation L x W x H110 x 91 x 305 in.
Weight, dry / wet1,548 lb / 1,755 lb

Swipe the table sideways to see every column.

Reference conditions: 1 bar absolute inlet pressure, 30 percent relative humidity, 77 degrees F inlet air. Sound power complies with 2000/14/EC. Wind stability figure is conditional — confirm with us for your site.

Options

Tell us how the tower will be towed, powered and stored and we will spec it at quote time. Retrofitting a hitch or a winch later costs more than specifying it now.

Mechanical

  • Spark arrestor
  • Towing hitch combo
  • Towing hitch, 2 in. ball coupling
  • Towing hitch, 2.5 in. ring
  • Adjustable towing support

Electrical

  • ELCB cubicle with universal socket
  • ELCB cubicle without socket
  • Cubicle with universal socket
  • Road light system
  • E-stop
  • Earth pin
  • Battery isolator
  • DC electric winch
  • Lc1003 controller

Chicago Pneumatic Light Tower FAQ

How much area does the CPLT V17 light?

79,222 sq ft at an average of 2 foot-candles, or 45,800 sq ft if you need to hold a 0.5 foot-candle minimum everywhere in the lit area. Which figure matters depends on your specification: average illuminance is the usual commercial measure, while a minimum illuminance requirement is common on highway and utility work.

How long does it run on a tank?

105 hours with all four floodlights on, from the 26 gallon tank at 0.24 gal/h. That is more than four full nights of unattended running, or roughly two weeks of typical 8-hour night shifts between fills. Oil service falls due every 250 hours.

Why SMD LED instead of COB?

Surface mount device LEDs spread the emitting area across many small packages rather than concentrating it in one chip, which gives a wider and more even distribution from the same electrical draw. Chicago Pneumatic rates the difference at about 20 percent more coverage than an equivalent COB LED tower. In practice it means fewer dark corners and less glare.

How high does the mast go, and does it rotate?

24 ft, raised manually, with 340 degrees of rotation so you can aim the array without moving the trailer. The tower is rated stable to 68 mph wind, though that figure is conditional and worth confirming with us against your site.

What engine is in it, and is it Tier 4 Final?

A Kohler KDW702, a two-cylinder naturally aspirated direct-injection diesel running at 1,800 rpm with 6 kW rated net output, and yes, it is Tier 4 Final. The alternator is a 4 kVA ACA132BL, IP23, class H insulation.

Can I tow it with a standard truck?

Yes. It weighs 1,548 lb dry and 1,755 lb wet, and folds to 75 x 48 x 91 in. for transport, which is well inside a half-ton pickup’s tow rating. Specify the hitch you need — combo, 2 in. ball or 2.5 in. ring — at quote time.

How do I buy one?

By phone, for now. The CPLT V17 is quoted rather than carted while we finish setting the product up. Call 1-888-883-5144 and we will price the tower, the options you need and the freight together.

Get CPLT V17 pricing and lead time

Tell us how the tower will be towed and what electrical options you need, and we will spec and price it the same day.

Same Day Shipping on orders by 4 PM Eastern · Denver, Colorado · Mon-Fri 7 AM to 4:30 PM MT